Brovind controllers represent the most advanced control technology available in the vibrating feeding and orientation field, the result of our decades of experience in the sector.

Thanks to our controllers we are able to offer interconnected control systems for the main automatic vibratory feed and orientation solutions, based on the most advanced criteria of industry 4.0. Our electronic devices ensure precision diagnostics, providing reports in real time useful for preventing malfunctions and for real time correction of production based on expected results and performance.


All Brovind controllers are built inside the company and are equipped with proprietary software.

Controller mod.

QCFF

The QCFF, used to control 4 electromagnet drive units completely independently, at 3000 or 6000 oscillations/min. They have an input voltage range from 110V to 230V, provide excellent control of vibrator speed and keep it constant over time via a feed-back sensor, including in the presence of variation of the electricity network and load. A memory area is available for entering Boolean logic to manage input sensors and output relays, start/stop, etc.
Equipped with RS485 serial communication (ASCII and MOD BUS RTU protocol)
Device with 14 A output available,  IP54 aluminium enclosure



A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H ø (mm)CERTIFICAZIONE ULDownload
QCFF (14A)20022016218025203,71805,5ULDownload file


ATTENZIONE : LE DIMENSIONI RIMANGONO IDENTICHE A PRESCINDERE DALLA CERTIFICAZIONE UL. CONSULTARE L'UFFICIO TECNICO PER ULTERIORI INFORMAZIONI

Controller mod.

CB-01

The CB-01, used to control electromagnet drive units, at 3000 or 6000 oscillations/min. They have an input voltage from 110V to 230V and control the vibrator speed. Start/stop etc. available.
Devices with 6 A output available,  IP54 aluminium enclosure
Bulk version available



A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H ø (mm)CERTIFICAZIONE ULDownload
CB_01100220851803203,7805,5//Download file


ATTENZIONE : LE DIMENSIONI RIMANGONO IDENTICHE A PRESCINDERE DALLA CERTIFICAZIONE UL. CONSULTARE L'UFFICIO TECNICO PER ULTERIORI INFORMAZIONI

Controller mod.

CB-02

The CB-02, used to control electromagnet drive units, at 3000 or 6000 oscillations/min. They have an input voltage from 110V or 230V, provide excellent control of vibrator speed and keep it constant over time via a feed-back sensor, including in the presence of variation of the electricity network and load. Start/stop etc. available.
Devices with 6 A output available,  IP54 aluminium enclosure
Bulk version available



A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H ø (mm)CERTIFICAZIONE ULDownload
CB_02100220981803203,7805,5//Download file


ATTENZIONE : LE DIMENSIONI RIMANGONO IDENTICHE A PRESCINDERE DALLA CERTIFICAZIONE UL. CONSULTARE L'UFFICIO TECNICO PER ULTERIORI INFORMAZIONI

Controller mod.

DCFF

The DCFF, used to control electromagnet drive units, at 3000 or 6000 oscillations/min. They have an input voltage from 110V or 230V, provide excellent control of vibrator speed and keep it constant over time via a feed-back sensor, including in the presence of variation of the electricity network and load. Start/stop etc. available.
Devices with 6 A output available,  IP54 aluminium enclosure



A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H ø (mm)CERTIFICAZIONE ULDownload
DCFF (10A)1002201771803203,7805,5ULDownload file


ATTENZIONE : LE DIMENSIONI RIMANGONO IDENTICHE A PRESCINDERE DALLA CERTIFICAZIONE UL. CONSULTARE L'UFFICIO TECNICO PER ULTERIORI INFORMAZIONI

Controller mod.

CFF

The CFF, used to control electromagnet drive units, at 3000 or 6000 oscillations/min. They have an input voltage range from 110V to 230V, provide excellent control of vibrator speed and keep it constant over time via a feed-back sensor, including in the presence of variation of the electricity network and load. A memory area is available for entering Boolean logic to manage input sensors and output relays, start/stop, etc.
Equipped with RS485 serial communication (ASCII and MOD BUS RTU protocol)
Devices with 6-15 A output available,  IP54 aluminium enclosure



A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H ø (mm)CERTIFICAZIONE ULDownload
CFF (6A)1002201371803203,7805,5ULDownload file
CFF (15A)10022017718015203,7805,5ULDownload file
CFF (10A-400V)20022017718025203,71805,5//Download file


ATTENZIONE : LE DIMENSIONI RIMANGONO IDENTICHE A PRESCINDERE DALLA CERTIFICAZIONE UL. CONSULTARE L'UFFICIO TECNICO PER ULTERIORI INFORMAZIONI

Controller mod.

CFV

CFV mod. controllers make it possible to run the vibrator at an ideal frequency for the material to feed. They possess an input voltage range from 110V to 230V and can feed the drive units at a frequency that will remain independent from that supplied by the electrical network. It is possible to determine the optimal work frequency via the feedback sensor.
A memory area is available for entering Boolean logic to manage input sensors and output relays, start/stop, etc.
Equipped with RS485 serial communication (ASCII and MOD BUS RTU protocol)
Devices with 4-6-12 A output available,  IP54 aluminium enclosure



A (mm)B (mm)C (mm)D (mm)E (mm)F (mm)G (mm)H ø (mm)CERTIFICAZIONE ULDownload
CFV (4A)1002201771803203,7805,5UL
CFV (6A)10022017718015203,7805,5UL
CFV (12A)2002201771803203,7805,5UL


ATTENZIONE : LE DIMENSIONI RIMANGONO IDENTICHE A PRESCINDERE DALLA CERTIFICAZIONE UL. CONSULTARE L'UFFICIO TECNICO PER ULTERIORI INFORMAZIONI

CFV (4A) CFV (6A) CFV (12A) CFF (6A) CFF (15A)  CFF (10A) DCFF (10A) QCFF (14A) CB-02 CB-01
Input voltage 400 AC ●
Input voltage 110-230 AC ● ● ● ● ● ● ●
Input voltage 110 or 230 AC ● ●
Frequency 50/60 Hz ● ● ● ● ● ● ● ● ● ●
Output current 4 A ●
Output current 6 A ● ● ● ●
Output current 10 A ● ●
Output current 12 A ●
Output current 14 A ●
Output current 15 A ●
Output current UL (amb. t 40 °C) 4 A ●
Output current UL (amb. t 40 °C) 5 A ●
Output current UL (amb. t 40 °C) 9 A ●
Output current UL (amb. t 40 °C) 10 A ● ●
Output current UL (amb. t 40 °C) 15 A ●
Output frequency 10-140 Hz ● ● ●
Output frequency 50 Hz ● ● ● ● ● ● ●
Setpoint via keyboard ● ● ● ● ● ● ● ●
Setpoint 0-10 VDC ● ● ● ● ● ● ● ● ● ●
Setpoint via potentiometer ● ●
Setpoint via optional potentiometer ● ● ● ● ● ● ●
Status relay ● ● ● ● ● ● ● ●
External valve control ● ● ● ● ● ● ● ●
Sensor power supply ● ● ● ● ● ● ● ● ●
Start setting Max ● ● ● ● ● ● ● ●
Soft start ● ● ● ● ● ● ● ●
Soft stop ● ● ● ● ● ● ● ●
2 Inputs ● ● ● ● ● ●
4 Inputs ● ●
PNP input type ● ● ● ● ● ● ● ● ●
Pre-set speed settings ● ● ● ● ● ● ● ●
Freq. search Resonance ● ● ● ● ● ● ●
Selectable programs ● ● ● ● ● ● ● ●
Settable time-out sensor ● ● ● ● ● ● ●
Short circuit control with alarm ● ● ●
Current limit control ● ● ●
Field bus interfaces (PN/EIP/PD/EthCAT/etc) ● ●
Standard Conformity CE ● ● ● ● ● ● ● ● ● ●
Standard Conformity UL/CSA ● ● ● ● ● ● ●
Protection class IP54 ● ● ● ● ● ● ● ● ● ●
Protection class IP20 ● ●
Ambient temperature 40° C max ● ● ● ● ● ● ● ● ● ●